Electrical cable shielded Halogen free

A MUST(!) for timber houses or construction with lightweight walls! 

For installation in dry, damp or wet rooms, but not outdoors. Use for fixed or flexible installation without tensile stress or forced guidance. As shielded signal and pulse cable in measurement and control technology, where the shielding serves as protection against external influences such as electrical magnetic fields, interference frequencies or similar.

Cores
Length

€175.00*

Patient price available

Available, delivery time: 2-5 days

Product number: KAB-2017-216

Shielded cables - Halogen-free control cable with EMC-optimised braided shielding and improved behaviour in case of fire

A MUST(!) for wooden houses or construction with lightweight walls!

A protective foil is wrapped around the electric cables, followed by an aluminium foil. An additional grounding wire runs inside, which has direct contact with the aluminium foil. The occurring voltage fields of the electric cables are directly intercepted there.
Please ensure that the appropriate cavity or plaster sockets are also ordered!   

Important ! Notes for the electrical contractor 

During installation, it is essential to connect the ground connection of the e.g. flush-mounted socket with the ground connection of the shielded installation cable used (yellow-green with yellow-green, never with the drain wire), protect the bare drain wire with an insulating tube (no conductive components in the junction box) and lead this (drain wire = shield connection, without connection to yellow-green) as far as possible to the equipotential bonding rail or distribution box. Always connect the shield wire to one side only, not to earth on both sides, as is sometimes the case in HF technology. Do not use unshielded and shielded installation cables mixed together.

Usage:

For installation in dry, damp or wet rooms, but not outdoors. Use for fixed or flexible installation without tensile stress or forced guidance. As shielded signal and pulse cable in measurement and control technology, where the shielding serves as protection against external influences such as electrical magnetic fields, interference frequencies or similar.

 

  Construction:

  1. Copper conductor, bare, fine-stranded
  2. Core insulation made of halogen-free, cross-linked polyolefin copolymer
  3. Cores foiled
  4. Braided shield made of tinned copper wires
  5. Outer sheath made of halogen-free, cross-linked polyolefin copolymer, grey

Standards:

according to DIN EN 50266-2-4 and DIN EN 50267-2-2 DIN EN 60228 class 5 (conductor construction) Core identification : 1 core gg, further cores sw with numbers (except in the 2-core version)

Technical specifications:

Rated voltage Uo/U: 300 / 500 Volt Test voltage: [V]AC 2000 Temperature range (moving): - 5°C to +70°C
Temperature range (fixed): -30°C to +70°C

   

Conductor bare, solid class 1 acc. to DIN 0295, sheath colour light grey RAL 7035, shield (electric field, 50 Hz mains voltage) plastic-coated aluminium strip with one tinned filler wire (copper, bare, solid), copper filler wire: 1.13 mm

Core insulation, halogen-free (cross-linked PE polyethylene 2XI1) according to DIN 0276 part 604

plastic inner sheath and outer sheath halogen-free PE-polymer compound HM2 according to DIN 0250 part 214
– Polymers PE-EVA mixture Granulate
– Flame retardant Aluminium trihydroxide (ATH) powder

No plasticisers processed

Rated voltage U0/U 300/500 V, current load according to VDE 0100

Structure according to DIN 0250 part 204/209, marking according to DIN 0293

Test method according to DIN 0472, part 266-2-4 test type C or IEC 332.3

Alternating test voltage 50 Hz, 2000 V

Bending radius according to DIN 0298, not moved approx. 4 x diameter

All standards related to Germany (VDE). NO approval outside the EU.